| Body Design Conditions | ANSI 600 |
|---|---|
| PMA Maximum Allowable Pressure | 103 bar g @ 93 °C |
| TMA Maximum Allowable Temperature | 525 °C 42.7 bar g |
| Minimum ambient temperature | -30 °C |
| PMOB | 80% of upstream pressure |
| Minimum Operating Pressure (MPaG) | 1.4 bar g |
| maximum cold hydraulic test pressure | 155 bar g |



Performance testing per ANSI/ASME PTC-39.1.
End connections per ANSI B1.20.1 for threaded ends, per ANSI B16.11 for socket welding ends.


ARIKE THERMODYNAMIC DISC TRAP WITH THERMOSTATIC AIR VENT
The TDX62LM thermodynamic steam trap has been specifically Designed for low capacity applications up to 62 bar.
TDX62LM benefits: